產品介紹
WP50
- FP-COMB 32
- FP-COMB 63/690-1
- FP-EFT 100M2
- FP-SURGE 100M2
- PCD 121
- PCD 126 A
- PCD 122
- DEC 5
- DEC 6
- DEC 7
Haefely
Coupling / Decoupling Networks (CDN)
EFT / Burst Immunity Test Systems
Electrostatic Discharge (ESD)
Power Frequency Magnetic Fields
Pulse Magnetic Field Test Systems
Software
水冷機零件
BONN
RF Power Amplifiers
RF Amplifier Modules
EMI Preamplifiers
Directional Couplers (internal and external)
Waveguide-Coax Adapter
RF Power Attenuators
RF Power Terminations
各式CDU
Cooling
- AMETEK TESEQ NSG 437
- 音壓放大器
二手儀器專區
TESEQ
Brüel & Kjær
- WP10M
- WP50
- WP400
- WP400-3
- WP400c
- WPF3
- WPF6
- WPF8
- WPF18
- WPF40
- WPF60
- WPF60S
- WPF90
- WPH60
- WPH1000
- WPH-DC
- 校正服務 (Calibration Services)
Wavecontrol
Field Probes
Calibrations
NOISEKEN -INS4040/4020水銀繼電器販賣
各式EMC ESD/CDN/LISN 維修
- KT-200SG
KAST
KT-200SG
- HD316
誠臻
電磁兼容
Schloeder GmbH
Band Reject Filter
- SGH-8 AC/DC- MF
- Fully AC/DC DIP compliant
SGH EMC System
AC/DC - MF
AC/DC-DIP
Power Ampilifer
- CDN S24 USB-C
- CDN S25 SUBD
- CDN T8 RJ45
- CDN T4 RJ45
- CDN T4 4A
- CDN T2 16A
Schwarzbeck
Coupling / Decoupling Networks
Pre-Amplifier
各式放大器訂製
低頻放大器
Todaisu
- TAF Calibration Lab
RF-Cable
High low Frequency cable
WP50
功能特點 (Features):
電場與磁場測量 (Electric & Magnetic field measurement)
各向同性與真實均方根測量 (Isotropic & True RMS measurement)
依據所選限值加權的探頭 (Probe weighted dependent on the selected limit)
符合 IEC 62110 與 IEC 61786 之測量 (Measurements in accordance with IEC 62110 and IEC 61786)
主要應用 (Main Applications):
能源 (Energy): IEC/EN 62110
感應加熱 (Induction heating): EN 50519
電弧或感應熔煉 (Electric arc or induction smelting)
工作場所評估 (Workplace assessment): EN 50499
人體暴露評估 (Human exposure assessment): EN 50413
其他低頻應用 (Other low frequency applications)
符合 IEC/EN 61786-1 標準 (In accordance with IEC/EN 61786-1)
詳細說明
| Frequency range | 10 Hz - 3 kHz |
| Sensor type | Isotropic, RMS Combined measurement of electric and magnetic fields |
| Type of frequency response | 1) Weighted (Results displayed in % of the selected standard) 2) Flat response (Results in V/m, µT, etc. ) |
| Exposure limits (probe in weighted mode) |
Public and occupational ICNIRP 2010 Customizable to other standards |
| Measurement range Weighted mode (ICNIRP 2010) Field Strength Mode |
E field: 0.025 % - 200 % of limit (RMS value) H field: 0.025 % - 200 % of limit (RMS value) E field: 2.5 V/m - 20000 V/m (RMS) H field: 0.25 µT - 2000 µT (RMS) |
| Dynamic range | 78 dB |
| Sensitivity | Weighted (E, H) 0.025 % Flat response E field 2.5 V/m Flat response H field 0.25 µT |
| Frequency response (*) | ± 20 % (typ.) of standard (25 Hz - 1 kHz) ± 25 % (max.) |
| Linearity | ± 1 % (typ.) (1 % - 100 % of standard) ± 2 % (max.) |
| Isotropic response | ± 5 % (typ.) |
| Calibration | ISO 17025 Accredited Calibration (ILAC) |
| Calibration period | 24 months (recommended) |
| Operating temperature | - 15 ºC to 50 ºC |
| Dimensions | 270 mm x 115 mm Ø |
| Field sensor area | 100 cm2 |
| Weight | 210 g |