產品介紹
WP400c
- FP-COMB 32
- FP-COMB 63/690-1
- FP-EFT 100M2
- FP-SURGE 100M2
- PCD 121
- PCD 126 A
- PCD 122
- DEC 5
- DEC 6
- DEC 7
Haefely
Coupling / Decoupling Networks (CDN)
EFT / Burst Immunity Test Systems
Electrostatic Discharge (ESD)
Power Frequency Magnetic Fields
Pulse Magnetic Field Test Systems
Software
- FD83 接頭
水冷機零件
接頭
BONN
RF Power Amplifiers
RF Amplifier Modules
EMI Preamplifiers
Directional Couplers (internal and external)
Waveguide-Coax Adapter
RF Power Attenuators
RF Power Terminations
各式CDU
Cooling
二手儀器專區
- WP10M
- WP50
- WP400
- WP400-3
- WP400c
- WPF3
- WPF6
- WPF8
- WPF18
- WPF40
- WPF60
- WPF60S
- WPF90
- WPH60
- WPH1000
- WPH-DC
- 校正服務 (Calibration Services)
Wavecontrol
Field Probes
Calibrations
NOISEKEN -INS4040/4020水銀繼電器販賣
各式EMC ESD/CDN/LISN 維修
- KT-200SG
KAST
KT-200SG
- HD316
誠臻
電磁兼容
Schloeder GmbH
Band Reject Filter
- SGH-8 AC/DC- MF
- Fully AC/DC DIP compliant
SGH EMC System
AC/DC - MF
AC/DC-DIP
Power Ampilifer
Schwarzbeck
Pre-Amplifier
各式放大器訂製
低頻放大器
Todaisu
- TAF Calibration Lab
RF-Cable
High low Frequency cable
WP400c
功能特點 (Features):
電場與磁場測量 (Electric & Magnetic field measurement)
各向同性與真實均方根測量 (Isotropic & True RMS measurement)
頻譜分析探頭 (Spectrum analysis probe)
符合國際標準的測量 (Measurements in accordance with International Standards)
100 cm² 感測器 (100 cm² sensor)
主要應用 (Main Applications):
汽車產業 (Automotive)
能源: IEC/EN 62110 (Energy: IEC/EN 62110)
鐵路: EN 50500 (Railway: EN 50500)
焊接: EN 50505 (Welding: EN 50505)
感應加熱(低頻): EN 50519 (Induction heating (LF): EN 50519)
電弧或感應熔煉 (Electric arc or induction smelting)
家用電器: IEC/EN 62233, EN 50366 (Household appliances: IEC/EN 62233, EN 50366)
RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1 (RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1)
醫療: IEC 60601 (Medical: IEC 60601)
研究/實驗室 (Research/Labs)
電子/電氣設備: IEC/EN 62311 (Electronic/electrical equipment: IEC/EN 62311)
國防(低頻) (Defense (LF))
工作場所評估: EN 50499 (Workplace assessment: EN 50499)
植入式醫療裝置從業人員評估: EN 50527-1 (Assessment of workers bearing AIMDs: EN 50527-1)
人體暴露評估: EN 50413 (Human exposure assessment: EN 50413)
符合 IEC/EN 61786-1 標準,並包含 GB 8702-2014 限值
(In accordance with IEC/EN 61786-1. GB 8702-2014 limit included.)
詳細說明
| Electric Field | Magnetic Field | |
| Sensor type | Isotropic patented electrodes | |
| Frequency range | 1 Hz – 400 kHz | |
| Field Strength Mode | ||
| Measurement range | 1 V/m to 100 kV/m | 50 nT - 30 mT @ 50 Hz 50 nT - 1.5 mT (820 Hz - 40 kHz) · Upper range increases linearly with decreasing frequency below 820 Hz. · Upper range decreases linearly with increasing frequency above 40 kHz. |
| Graphical display | RMS, Axis Values, AVG, MAX, MIN, PEAK, RMS time graph | |
| Peak value | digital realtime | digital realtime |
| Resolution | < 0.4 mV/m above 8 Hz | < 0.1 nT (at 50 Hz) and < 0.05 nT above 100 Hz |
| Noise level | < 1 V/m (10 Hz - 400 kHz) | < 50 nT (10 Hz – 400 kHz) |
| Weigthed Peak Method mode | ||
| Measurement range | 200 % (min) | 200 % (min) |
| Graphical display | PEAK (%), AXIS VALUES (%), AVG (%), MAX (%), MIN (%), RMS (%), Time graph |
|
| Standards/Limits | EU Directive 2013/35/EU, IEEE (except Restricted and Limb), ICNIRP, BGV B11, GB 8702-2014. Easy software update to future modifications and to other limits. |
|
| FFT Mode | ||
| Measurement range | 4 mV/m – 100 kV/m | 0.5 nT - 30 mT @ 50 Hz 0.5 nT - 1.5 mT (820 Hz - 40 kHz) · Upper range increases linearly with decreasing frequency below 820 Hz. · Upper range decreases linearly with increasing frequency above 40 kHz. |
| Graphical display | Frequency analysis, total field and axes | |
| SPAN(Resolution) | 400 Hz (1 Hz) - 4 kHz (10 Hz) - 40 kHz (100 Hz) - 400 kHz (1 kHz) | |
| Noise level | < 4 mV/m | < 0.5 nT |
| FFT | 1024 point FFT | |
| General specifications | ||
| Isotropy | ± 5 % | ± 4 % |
| Typical Uncertainty | 8 % (0.67 dB) | 7.2 % (0.60 dB) |
| Temperature deviation [typ. at 60 Hz] (referred to 25 °C, 50 % relative humidity) |
- 0.005 dB/°C (- 15 °C to 40 °C) | - 0.003 dB/°C (- 15 °C to 25 °C) + 0.003 dB/°C (25 °C to 40 °C) |
| Damage level | > 200 kV/m | > 2000 mT up to 60 Hz Damage level decreases linearly with increasing frequency above 60 Hz |
| Linearity | ± 1 % (typ.) ± 2 % (max.) |
|
| Weight | 220 g | |
| Probe size | 280 mm x 128 mm Ø | |