產品介紹
WPF3
- FP-COMB 32
- FP-COMB 63/690-1
- FP-EFT 100M2
- FP-SURGE 100M2
- PCD 121
- PCD 126 A
- PCD 122
- DEC 5
- DEC 6
- DEC 7
Haefely
Coupling / Decoupling Networks (CDN)
EFT / Burst Immunity Test Systems
Electrostatic Discharge (ESD)
Power Frequency Magnetic Fields
Pulse Magnetic Field Test Systems
Software
水冷機零件
BONN
RF Power Amplifiers
RF Amplifier Modules
EMI Preamplifiers
Directional Couplers (internal and external)
Waveguide-Coax Adapter
RF Power Attenuators
RF Power Terminations
各式CDU
Cooling
- AMETEK TESEQ NSG 437
- 音壓放大器
二手儀器專區
TESEQ
Brüel & Kjær
- WP10M
- WP50
- WP400
- WP400-3
- WP400c
- WPF3
- WPF6
- WPF8
- WPF18
- WPF40
- WPF60
- WPF60S
- WPF90
- WPH60
- WPH1000
- WPH-DC
- 校正服務 (Calibration Services)
Wavecontrol
Field Probes
Calibrations
NOISEKEN -INS4040/4020水銀繼電器販賣
各式EMC ESD/CDN/LISN 維修
- KT-200SG
KAST
KT-200SG
- HD316
誠臻
電磁兼容
Schloeder GmbH
Band Reject Filter
- SGH-8 AC/DC- MF
- Fully AC/DC DIP compliant
SGH EMC System
AC/DC - MF
AC/DC-DIP
Power Ampilifer
- CDN S24 USB-C
- CDN S25 SUBD
- CDN T8 RJ45
- CDN T4 RJ45
- CDN T4 4A
- CDN T2 16A
Schwarzbeck
Coupling / Decoupling Networks
Pre-Amplifier
各式放大器訂製
低頻放大器
Todaisu
- TAF Calibration Lab
RF-Cable
High low Frequency cable
WPF3
功能特點 (Features):
電場測量 (Electric field measurement)
各向同性與真實 RMS 測量 (Isotropic & True RMS measurement)
高靈敏度,自 0.2 V/m 起 (High sensitivity from 0.2 V/m)
在 50/60 Hz 下具優異衰減效果 (Excellent attenuation at 50/60 Hz)
符合國際標準之測量 (Measurements in accordance with International Standards)
主要應用 (Main Applications):
無線電信網路 (Wireless telecom networks) :IEC 62232, EN 50400, EN 50401
廣播 (Broadcast) :IEC 6251237, EN 50475, EN 50476, EN 50496, EN 50554
射頻識別/電子防盜 (RFID/EAS) :EN 50364, EN 50357, IEC/EN 62369-1
感應加熱 (高頻) (Induction heating, HF) :EN 50519
塑膠焊接 (Plastic welding)
半導體製造 (Semiconductor production)
醫療 (Medical) :IEC 60601
工作場所評估 (Workplace assessment) :EN 50499
植入式醫療裝置工作者之評估 (Assessment of workers bearing AIMDs) :EN 50527-1
人體暴露評估 (Human exposure assessment) :EN 50413
研究/實驗室 (Research/Labs)
微波乾燥 (Microwave drying)
詳細說明
| WPF3 | WPF3-HP High Power version |
|
| Frequency range | 100 kHz – 3 GHz | |
| Sensor type | Isotropic RMS diode technology |
|
| Type of frequency response | Flat | |
| Measurement range | 0.2 – 130 V/m (CW) 0.2 – 20 V/m (RMS) |
0.2 – 1000 V/m (CW) 0.2 – 20 V/m (RMS) |
| Dynamic range | 52 dB | 74 dB |
| Sensitivity | 0.2 V/m | |
| Resolution | 0.02 V/m (until 7.5 V/m) < 2 % (starting from 7.5 V/m) |
|
| Frequency response (*) | ± 1.5 dB (250 kHz – 3 GHz) - 3 dB (100 kHz) |
|
| Linearity | ±0.5 dB (0.5 V/m – 100 V/m) | |
| Isotropic deviation | ± 1.2 dB (@ 2 GHz) | |
| Calibration | ISO 17025 Accredited Calibration (ILAC) | |
| Calibration period | 24 months (recommended) | |
| Temperature range | - 20 ºC to 50 ºC | |
| Temperature response | + 0.1 / - 1 dB (related to 20 ºC) | |
| Dimensions | 28,4 cm X 6 cm Ø | |
| Weight | 95 g | |
| Attenuation at 50/60 Hz | >80 dB | |